Datasheet excerpt: Technical data of OCT300-M1K-N2
Product Description
Diffuse mode sensor, NAMUR, special design, 300 mm detection range, infrared light, light/dark on, DC version, NAMUR output, terminal compartment
General specifications
Detection range 0 ... 300 mm
Adjustment range 70 ... 300 mm
Reference target standard white 200 mm x 200 mm
Light source IRED , 880 nm
Light type modulated infrared light
Ambient light limit ≤ 40000 Lux sun light
≤ 30000 Lux halogen light
Temperature influence ≤ 0.5 mm/K
Functional safety related parameters
MTTFd 1319 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Function indicator LED yellow: switching state
Control elements Sensing range adjuster
Electrical specifications
Operating voltage 6 ... 20 V DC (Ri approx. 0 Ohm)
Ripple 5 %
Time delay before availability 20 ms
Output
Switching type light/dark on, programmable
Signal output 1 NAMUR output NC/NO programmable
Switching voltage 8 V DC (Ri approx. 1 kΩ)
Switching frequency ≤ 100 Hz
Current consumption
Reference target detected connection 1, 2: ≤ 1 mA
connection 3, 4: ≥ 2.7 mA
Reference target not detected connection 1, 2: ≥ 2.7 mA
connection 3, 4: ≤ 1 mA
Response time 5 ms
Repeat accuracy ≤ 0.5 % of the sensing range
Conformity
Product standard EN 60947-5-2
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-6:2000
Approvals and certificates
FM approval
Approved for IS / I,II,III / 1 / ABCDEFG / T5 - 116-0110; Entity
NI / I / 2 / ABCD / T6
Entity Parameters:
VMax = 12.6 V, IMax = 20 mA, Ci = 1.11 µF, Li = 0 mH (Groups A, B, C, D, E, F, G).
VMax = 15.5 V, IMax = 52 mA, Ci = 1.11 µF, Li = 0 mH (Groups C, D, E, F, G).
CSA approval
Approved for Class I, Division 2, Groups A, B, C and D
Rated 20V (max), 50mA.
These sensors are suitable for installation in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit, as acceptable to the local inspection authority having jurisdiction.
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions OCT300-M1K-N2
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Housing width 30 mm
Housing height 30 mm
Housing depth 102 mm
Degree of protection IP20
Connection M16 terminal compartment, core cross section ≤ 2.5 mm2
Material
Housing PBT
Optical face Scratch resistant mineral glass lens
Mass 100 g
ATEX G
EC-Type Examination Certificate PTB 01 ATEX 2203 X
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
CE marking CE0102
ATEX marking Zone 1: Ex-Hexagon II 2G Ex ia op is IIC T6...T1 Gb
Directive conformity 2014/34/EU
Standards EN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
Effective internal capacitance Ci max. 75 nF
Effective internal inductance Li negligibly small
General The apparatus must be operated in accordance with the data provided in the datasheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Special conditions
OCT300-M1K-N2
Protection from mechanical danger When used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing.
Degree of protection required when installing connecting components IP20 according to IEC 60529:2001
Other conditions Refer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner
Quảng cáo
Quảng cáo
Chi tiết : | |
---|---|
Mã tin | 231898 |
Loại tin | Bán |
Giá | Liên hệ |
Chuyên mục | Thiết bị cảm biến |
Ngày đăng | 19/06/2023 |
Lượt xem | 40 |
Nơi đăng | Quận Cầu Giấy, Hà Nội |
Báo tin không hợp lệ
|
|
Theo dõi tin này |
Thông tin người bán | |
Mr Thanh |
|
0965130856 | |
Sản phẩm cùng người bán |
Chia sẻ tin đăng lên (facebook, twitter, google+,...)